8 / 29 page Operation M41T11 8/29 2 Operation The M41T11 clock operates as a slave device on the serial bus. Access is obtained by implementing a start condition followed by the correct slave address (D0h). The 64 bytes contained in the device can then be accessed sequentially in the following order: ● 1st Byte: seconds register ● 2nd Byte: minutes register ● 3rd Byte: century/hours register ● 4th Byte: day register ● 5th Byte: date register ● 6th Byte: month register ● 7th Byte: years register ● 8th Byte: control register ● 9th - 64th Bytes: RAM The M41T11 clock continually monitors VCC for an out of tolerance condition. Should VCC fall below VSO, the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from an out of tolerance system. When VCC falls below VSO, the device automatically switches over to the battery and powers down into an ultra low current mode of operation to conserve battery life. Upon power-up, the device switches from battery to VCC at VSO and recognizes inputs. 2.1 2-wire bus characteristics This bus is intended for communication between different ICs. It consists of two lines: one bi-directional for data signals (SDA) and one for clock signals (SCL). Both the SDA and the SCL lines must be connected to a positive supply voltage via a pull-up resistor. The following protocol has been defined: ● Data transfer may be initiated only when the bus is not busy. ● During data transfer, the data line must remain stable whenever the clock line is High. ● Changes in the data line while the clock line is High will be interpreted as control signals. Accordingly, the following bus conditions have been defined: 2.1.1 Bus not busy. Both data and clock lines remain High. 2.1.2 Start data transfer. A change in the state of the data line, from High to Low, while the clock is High, defines the START condition. |
Podobny numer części - M41T11MH6F |
|
Podobny opis - M41T11MH6F |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |