10 / 68 page AD5560 Data Sheet Rev. D | Page 10 of 68 Parameter Min Typ Max Unit Test Conditions/Comments Comparator DAC Dynamic Output Voltage Settling Time1 3.5 6 µs 1 V change to 1 LSB. Slew Rate1 1 V/µs Digital-to-Analog Glitch Energy1 10 nV-s Glitch Impulse Peak Amplitude1 40 mV REFERENCE INPUT VREF DC Input Impedance 1 MΩ Typically 100 MΩ. VREF Input Current −10 +10 µA Per input; typically ±30 nA. VREF Range1 2 5 V COMPARATOR Measured directly at comparator; does not include measure block errors. Error −7 +7 mV Uncalibrated. VOLTAGE COMPARATOR With respect to the measured voltage. Propagation Delay1 0.25 µs Error1 −12 +12 mV Uncalibrated. CURRENT COMPARATOR Propagation Delay1 0.25 1 µs Error1 −1.5 +1.5 % Of programmed current range, uncalibrated. MEASURE OUTPUT, MEASOUT Measure Output Voltage Span1 −12.81 +12.81 V MEASOUT gain = 1, VREF = 5 V, offset DAC = 0x8000. Measure Output Voltage Span1 −6.405 +6.405 V MEASOUT gain = 1, VREF = 2.5 V. Measure Output Voltage Span1 0 5.125 V MEASOUT gain = 0.2, VREF = 5 V, offset DAC = 0x8000. Measure Output Voltage Span1 0 2.56 V MEASOUT gain = 0.2, VREF = 2.5 V. Measure Pin Output Impedance 115 Ω Output Leakage Current −100 +100 nA When HW_INH is low. Output Capacitance1 5 pF Short-Circuit Current1 −10 +10 mA OPEN-SENSE DETECT/CLAMP/ALARM Measurement Accuracy −200 +200 mV Clamp Accuracy 600 900 mV Alarm Delay1 50 μs DUTGND Voltage Range1 −1 +1 V Pull-Up Current +50 +70 μA Pull-up for purpose of detecting open circuit on DUTGND, can be disabled. Leakage Current −1 +1 μA When pull-up disabled, DGS DAC = 0x3333 (1 V with VREF = 5 V). If DUTGND voltage is far away from one of comparator thresholds, more leakage may be present. Trip Point Accuracy −30 +10 mV Alarm Delay1 50 μs GUARD AMPLIFIER Voltage Range1 AVSS + 2.25 AVDD − 2.25 V Voltage Span1 25 V Output Offset −10 +10 mV Short-Circuit Current1 −20 +20 mA Load Capacitance1 100 nF Output Impedance 100 Ω Alarm Delay1 200 μs If it moves 100 mV away from input level. DIE TEMPERATURE SENSOR Accuracy1 −10 +10 % Relative to a temperature change. Output Voltage at 25°C 1.54 V Output Scale Factor1 4.7 mV/°C Output Voltage Range1 1 2 V |
Podobny numer części - AD5560JBCZ |
|
Podobny opis - AD5560JBCZ |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |