Zakładka z wyszukiwarką danych komponentów |
|
TS122STR Arkusz danych(PDF) 4 Page - Clare, Inc. |
|
TS122STR Arkusz danych(HTML) 4 Page - Clare, Inc. |
4 / 8 page www.clare.com 4 TS122 Rev. 7 PERFORMANCE DATA* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. TS122 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C; IF = 5mADC) 35 30 25 20 15 10 5 0 1.17 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) TS122 Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load: Voltage = 250VDC; Current = 170mADC; I F = 5mADC) 35 30 25 20 15 10 5 0 5.5 7.5 9.5 11.5 6.5 8.5 10.5 On-Resistance ( Ω) TS122 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 305 325 345 365 315 335 355 Blocking Voltage (V) TS122 Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 0.5 0.9 1.3 0.3 0.7 1.1 1.5 LED Current (mA) 25 20 15 10 5 0 TS122 Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 25 20 15 10 5 0 0.45 1.05 1.65 0.15 0.75 1.35 1.95 LED Current (mA) TS122 Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.625 1.125 1.625 2.125 0.875 1.375 1.875 Turn-On (ms) 25 20 15 10 5 0 TS122 Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.335 0.715 1.095 1.475 1.285 0.905 0.525 Turn-Off (ms) 25 20 15 10 5 0 TS122 Typical Load Current vs. Temperature Temperature ( °C) 250 200 150 100 50 0 -40 -20 0 20 40 60 80 120 100 20mA 10mA 5mA TS122 Typical Leakage vs. Temperature (Measured across Pins 7 & 8) Temperature ( °C) -40 0.025 0.020 0.015 0.010 0.005 0 -20 0 20 40 60 80 100 TS122 Typical Blocking Voltage vs. Temperature Temperature ( °C) -40 350 345 340 335 330 325 320 315 -20 0 20 40 60 80 100 TS122 Typical Turn-On vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 -20 0 20 40 60 80 100 5mA 10mA 20mA TS122 Typical Turn-Off vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 0.700 0.600 0.500 0.400 0.300 0.200 0.100 0 -20 0 20 40 60 80 100 5mA |
Podobny numer części - TS122STR |
|
Podobny opis - TS122STR |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |