Zakładka z wyszukiwarką danych komponentów |
|
HCPL3140 Arkusz danych(PDF) 4 Page - Agilent(Hewlett-Packard) |
|
HCPL3140 Arkusz danych(HTML) 4 Page - Agilent(Hewlett-Packard) |
4 / 16 page 4 Solder Reflow Temperature Profile Regulatory Information The HCPL-3140/HCPL-0314 are pending approval by the following organizations: VDE Approval under VDE 0884/06.92 with VIORM = 630 Vpeak (HCPL-3140) and 566 Vpeak for HCPL-0314. UL Approval under UL 1577, component recognition program up to VISO = 2500 Vrms expected prior to product release. File E55361. CSA Approval under CSA Component Acceptance Notice #5, File CA 88324 expected prior to product release. VDE 0884 Insulation Characteristics (HCPL-3140 Option 060) Description Symbol Characteristic Unit Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 Vrms I - IV for rated mains voltage ≤ 300 Vrms I - III for rated mains voltage ≤ 600 Vrms I-II Climatic Classification 55/100/21 Pollution Degree (DIN VDE 0110/1.89) 2 Maximum Working Insulation Voltage VIORM 630 Vpeak Input to Output Test Voltage, Method b* VIORM x 1.875=VPR, 100% Production Test with VPR 1181 Vpeak tm=1 sec, Partial discharge < 5 pC Input to Output Test Voltage, Method a* VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec, VPR 945 Vpeak Partial discharge < 5 pC Highest Allowable Overvoltage VIOTM 6000 Vpeak (Transient Overvoltage tini = 10 sec) Safety-limiting values - maximum values allowed in the event of a failure. Case Temperature TS 175 °C Input Current** IS,INPUT 230 mA Output Power** PS, OUTPUT 600 mW Insulation Resistance at TS, VIO = 500 V RS >109 Ω * Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (VDE 0884) for a detailed description of Method a and Method b partial discharge test profiles. ** Refer to the following figure for dependence of PS and IS on ambient temperature. 0 TIME (SECONDS) 200 100 50 150 100 200 250 300 0 30 SEC. 50 SEC. 30 SEC. 160°C 140°C 150°C PEAK TEMP. 245°C PEAK TEMP. 240°C PEAK TEMP. 230°C SOLDERING TIME 200°C PREHEATING TIME 150°C, 90 + 30 SEC. 2.5°C ± 0.5°C/SEC. 3°C + 1°C/–0.5°C TIGHT TYPICAL LOOSE ROOM TEMPERATURE PREHEATING RATE 3°C + 1°C/–0.5°C/SEC. REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC. |
Podobny numer części - HCPL3140 |
|
Podobny opis - HCPL3140 |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |