Zakładka z wyszukiwarką danych komponentów |
|
AD5522 Arkusz danych(PDF) 4 Page - Analog Devices |
|
AD5522 Arkusz danych(HTML) 4 Page - Analog Devices |
4 / 45 page AD5522 Preliminary Technical Data Rev. PrL | Page 4 of 45 SPECIFICATIONS Table 1. AVDD ≥ 10V, AV SS ≤ −5V, |AV DD – AVSS| ≥ 20V and ≤ 33V, DV CC = 2.3V to 5.25V, VREF=5V, Gain (m), Offset (c) and DAC Offset registers at default values (TJ = +25 to +90oC, max specs unless otherwise noted.) Parameter Min Typ1 Max Units Test Conditions/Comments FORCE VOLTAGE FOH Output Voltage Range AVSS+4 AVDD-4 V All current ranges from FOH at full scale current. Includes ±1V dropped across sense resistor EXTFOH Output Voltage Range AVSS+3 AVDD-3 V External high current range at full scale current. Does not include ±1V dropped across sense resistor Output Voltage Span 22.5 V Offset Error -100 100 mV Offset Error Tempco2 ±100 µV/oC Gain Error -0.5 0.5 % Gain Error Tempco2 ±10 ppm/oC Linearity Error -0.02 0.02 % FSR FSR = Fullscale Range. ±10 V range, Gain and offset errors calibrated out. Short Circuit Current Limit2 -120 120 mA On 64mA range. -10 10 mA In all other ranges. MEASURE CURRENT MEASURE = (IDUT X RSENSE x GAIN) Offset Error -1 1 % V(Rsense)= ±1V Offset Error Tempco2 ±10 µV/oC Gain Error -1 1 % Instrumentation Amp Gain = 5 or 10 Gain Error Tempco2 25 ppm/oC Linearity Error -0.01 0.01 % FSCR Offset and Gain errors calibrated out Output Voltage Span2 22.5 V CM Error -0.005 0.005 %FSCR/V % of FS Change at measure output per V change in DUT voltage Measure Current Ranges ±5 µA Set using internal sense resistor ±20 µA Set using internal sense resistor ±200 µA Set using internal sense resistor ±2 mA Set using internal sense resistor Up to ±64 mA Set using external sense resistor, internal amplifier can drive to 64mA FORCE CURRENT Voltage Compliance, FOH AVSS+4 AVDD-4 V Voltage Compliance, EXTFOH AVSS+3 AVDD-3 V Offset Error -2 2 %FSCR Offset Error Tempco2 ±10 ppm FS/ oC Gain Error -0.5 0.5 % Gain = 1 Gain Error Tempco2 ±25 ppm/oC Linearity Error -0.02 0.02 % FSCR CM Error -0.005 0.005 %FSCR/V % of FS Change at measure output per V change in DUT voltage Force Current Ranges ±5 µA Set using internal sense resistor, 200kΩ ±20 µA Set using internal sense resistor, 50kΩ ±200 µA Set using internal sense resistor, 5kΩ ±2 mA Set using internal sense resistor, 500Ω Up to ±64 mA Set using external sense resistor, internal amplifier can drive to 64mA MEASURE VOLTAGE Measure Voltage Range AVDD-4 V AVSS+4 V Offset Error -10 10 mV Offset Error Tempco2 ±10 µV/oC Gain Error -0.5 0.5 % FSR Gain = 1 Gain Error Tempco2 ±10 ppm/oC Linearity Error -0.01 0.01 % FSR |
Podobny numer części - AD5522 |
|
Podobny opis - AD5522 |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |