5 / 12 page © 2006 Microchip Technology Inc. DS21441C-page 5 TC623 4.0 TYPICAL APPLICATIONS 4.1 Mounting If the TC623 is used to measure the temperature of another device, it is important that the top surface of the TC623 package be in intimate contact with the measured device. Good thermal conductivity and no air space is critical to accurate temperature measurement in applications of this type. 4.2 Trip Point Programming The resistance values required for the HIGH SET and LOW SET inputs are calculated using the formula below: For example, to program a trip point of 50°C, the programming resistor is: RTRIP = 0.5997 x T 2.1312 Where; RTRIP = Programming resistor value in Ohms T = Desired trip temperature in degrees Kelvin. RTRIP = 0.5997 x (50 + 273.15) 2.1312) = 133.65 k Ω |
Podobny numer części - TC623_06 |
|
Podobny opis - TC623_06 |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |