1 / 2 page SPECIFICATIONS MODEL ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 INPUT VOLTAGE[V] AC85 - 264 1 f or DC 120 - 350 (AC64 or DC90 optionally available *6) FREQUENCY[Hz] 50/60 (47-63) or DC EFFICIENCY[%] ACIN 100V 84typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) ACIN 200V 86typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 89typ (Io=100%) POWER FACTOR ACIN 100V 0.99typ (Io=100%) ACIN 200V 0.98typ (Io=100%) INRUSH CURRENT[A] ACIN 100V*1 20typ (Io=100%)(More than 3sec.to re-start) ACIN 200V*1 40typ (Io=100%)(More than 3sec.to re-start) LEAKAGE CURRENT[mA] 0.75max (60Hz, According to IEC60950 and DEN-AN)(Io=100%) OUTPUT VOLTAGE[V] 24 30 36 48 CURRENT[A] ACIN 100V*2 14 (Peak 25) convection 11 (Peak 20) convection 9 (Peak 16.5) convection 6.5 (Peak 12.5) convection ACIN 100V*2 21 (Peak 25) forced air 16.5 (Peak 20) forced air 14 (Peak 16.5) forced air 10.5 (Peak 12.5) forced air ACIN 200V*2 15 (Peak 31) convection 12 (Peak 24.5) convection 10 (Peak 20.5) convection 7 (Peak 15.5) convection ACIN 200V*2 25 (Peak 31) forced air 20 (Peak 24.5) forced air 16.5 (Peak 20.5) forced air 12.5 (Peak 15.5) forced air LINE REGULATION[mV] 96max 120max 144max 192max LOAD REGULATION[mV] 150max 180max 240max 300max RIPPLE[mVp-p] 0to+50 C*3 120max 160max 200max 200max -10 - 0 C*3 160max 230max 260max 300max RIPPLE NOISE[mVp-p] 0to+50 C*3 150max 190max 230max 250max -10 - 0 C*3 180max 250max 280max 400max TEMPERATURE REGULATION[mV] 0to+50 C 240max 300max 360max 480max DRIFT[mV] *4 96max 120max 144max 192max START-UP TIME[ms] 500max (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 27.0 27.0 - 33.0 33.0 - 41.0 41.0 - 52.8 OUTPUT VOLTAGE SETTING[V] 23.5 - 24.5 29.0 - 31.0 35.0 - 37.0 47.0 - 49.0 PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 101% of peak current and recovers automatically OVERVOLTAGE PROTECTION[V] 31 - 34.5 40 - 48 51 - 60 64 - 76 OPERATING INDICATION LED (Green) ALARM OUTPUT Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5) REMOTE ON/OFF(RC) Requirement for external source (Option : -R, refer to Instruction Manual 5) ISOLATION INPUT-OUTPUT -RC *5 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M W min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M W min (At Room Temperature) OUTPUT -RC-FG *5 AC500V 1minute, Cutoff current = 100mA, DC500V 50M W min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71 C, 20 - 90%RH (Non condensing)(Refer to DERATING CURVE), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) CONDUCTED NOISE Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 65 X127X195mm (WXHXD)(without terminal block) /1.5kg max COOLING METHOD Convection/Forced air *1 The value is primary surge.The current of input surge to a built-in noise filter (0.2ms or less) is excluded. *2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown in Instruction Manual 2.3. *3 This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101). *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *5 Applicable when remote control (optional) is added. *6 Derating is required.Consult us for details. * A sound may occur from power supply at pulse loading. ADA600F Unit type ADA 600 F -24 - O Ordering information 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional G :Low leakage current E :Low leakage current and EMI class A F :with Fan unit(only -24) T :Vertical terminal block J :Connector type C :with Coating R :Remote ON/OFF N1:DIN rail W:Alarms and Redundant operation Specification is changed at option,refer to Instruction Manual. R 12345 ADA A-120 Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air. Recommended Noise Filter NAC-20-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice |
Podobny numer części - ADA600F-24-N |
|
Podobny opis - ADA600F-24-N |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |