7 / 40 page Data Sheet ADV202 Rev. D | Page 7 of 40 NORMAL HOST MODE—READ OPERATION Table 4. Parameter Description Min Typ Max Unit t ACK [dir] RD to ACK, Direct Registers and FIFO Accesses 5 1.5 × JCLK1 + 7.0 ns t ACK [indir] RD to ACK, Indirect Registers 10.5 × JCLK 15.5 × JCLK + 7.0 ns t DRD [dir] Read Access Time, Direct Registers 5 1.5 × JCLK + 7.0 ns t DRD [indir] Read Access Time, Indirect Registers 10.5 × JCLK 15.5 × JCLK + 7.0 ns t HZRD Data Hold 2 8.5 ns t SC CS to RD Setup 0 ns t SA Address Setup 2 ns t HC CS Hold 0 ns t HA Address Hold 2 ns t RH Read Inactive Pulse Width 2.5 JCLK t RL Read Active Pulse Width 2.5 JCLK t RCYC Read Cycle Time, Direct Registers 5.0 JCLK 1 For a definition of JCLK, see the PLL section. ADDR HDATA tSA tSC tHC tRL tACK tDRD tHZRD tRH tRCYC tHA CS RD ACK VALID Figure 3. Normal Host Mode—Read Operation |
Podobny numer części - ADV202BBCZRL-115 |
|
Podobny opis - ADV202BBCZRL-115 |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |