6 / 16 page ADuM4121/ADuM4121-1 Data Sheet Rev. 0| Page 6 of 16 ABSOLUTE MAXIMUM RATINGS Ambient temperature = 25°C, unless otherwise noted. Table 7. Parameter Rating Storage Temperature Range (TST) −55°C to +150°C Junction Operating Temperature Range (TJ) −40°C to +125°C Supply Voltages VDD1 to GND1 −0.3 V to +7 V VDD2 to GND2 −0.3 V to +40 V Input Voltages VI+, VI−1 −0.3 V to +7 V VCLAMP2 −0.3 V to VDD2 + 0.3 V Output Voltages VOUT2 −0.3 V to VDD2 + 0.3 V Common-Mode Transients (|CM|)3 −200 kV/µs to +200 kV/µs 1 Rating assumes VDD1 is above 2.5 V. VI+ and VI− are rated up to 6.5 V when VDD1 is unpowered. 2 Referenced to GND2, maximum of 40 V. 3 |CM| refers to common-mode transients across the insulation barrier. Common-mode transients exceeding the Absolute Maximum Rating can cause latch-up or permanent damage. Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. THERMAL RESISTANCE Thermal performance is directly linked to printed circuit board (PCB) design and operating environment. Careful attention to PCB thermal design is required. θJA is thermal resistance, junction to ambient (°C/W). Table 8. Thermal Resistance Package Type θJA Unit RI-8-11 104.2 °C/W 1 Test Condition 1: thermal impedance simulated values are based on a 4-layer PCB. ESD CAUTION Table 9. Maximum Continuous Working Voltage1 Parameter Rating Unit Constraint AC Voltage Bipolar Waveform Basic Insulation 849 V peak 50-year minimum insulation lifetime Reinforced Insulation 789 V peak Lifetime limited by package creepage maximum approved working voltage per IEC 60950-1 Unipolar Waveform Basic Insulation 1698 V peak 50-year minimum insulation lifetime Reinforced Insulation 849 V peak 50-year minimum insulation lifetime DC Voltage Basic Insulation 1118 V peak Lifetime limited by package creepage maximum approved working voltage per IEC 60950-1 Reinforced Insulation 558 V peak Lifetime limited by package creepage maximum approved working voltage per IEC 60950-1 1 Maximum continuous working voltage refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details. Table 10. Truth Table VI− VI+ VDD1 State VDD2 State VOUT Output Don’t care Low Powered Powered Low Low High Powered Powered High High Don’t care Powered Powered Low Don’t care Don’t care Unpowered Powered Low Don’t care Don’t care Powered Unpowered Low1 1 The output is low, but not actively driven because the device is not powered. |
Podobny numer części - ADuM4121-1BRIZ |
|
Podobny opis - ADuM4121-1BRIZ |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |