10 / 22 page CD5.241 CD-Series DC/DC Converter 24V, 5A 10. TERMINALS AND WIRING Input Output Type screw terminals screw terminals Solid wire max. 6mm2 max. 6mm2 Stranded wire max. 4mm2 max. 4mm2 American Wire Gauge 20-10 AWG 20-10 AWG Wire stripping length 7mm / 0.275inch 7mm / 0.275inch Screwdriver 3.5mm slotted or Pozidrive No 2 3.5mm slotted or Pozidrive No 2 Recommended tightening torque 1Nm, 9lb.in 1Nm, 9lb.in Instructions: a) The external circuitry of all terminals must meet the safety requirements stipulated by IEC/EN/UL 60950-1: SELV. b) Use appropriate copper cables that are designed for an operating temperature of: 60°C for ambient up to 45°C and 75°C for ambient up to 60°C minimum. c) Follow national installation codes and installation regulations! d) Ensure that all strands of a stranded wire enter the terminal connection! e) Do not load the terminals with more than 25A! See section 21.9 f) Screws of unused terminal compartments should be securely tightened. g) Ferrules are allowed. h) Do not connect or disconnect the wires from the terminals below -25°C (-13°F). 11. RELIABILITY Input 24Vdc Lifetime expectancy *) 183 000h at 24V, 2.5A and 40°C 65 000h at 24V, 5A and 40°C 37 000h at 24V, 6A and 40°C 185 000h at 24V, 5A and 25°C MTBF **) SN 29500, IEC 61709 1 178 000h at 24V, 5A and 40°C 1 932 000h at 24V, 5A and 25°C MTBF **) MIL HDBK 217F 625 000h at 24V, 5A and 40°C; Ground Benign GB40 838 000h at 24V, 5A and 25°C; Ground Benign GB25 *) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The prediction model allows only a calculation of up to 15 years from date of shipment. **) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. Mar. 2016 / Rev. 1.5 DS-CD5.241-EN All parameters are specified at 24V, 5A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/22 |
Podobny numer części - CD5.241 |
|
Podobny opis - CD5.241 |
|
|
Link URL |
Polityka prywatności |
ALLDATASHEET.PL |
Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |